Current to Pressure Transducer
Vibration Resistant, NEMA 4X Enclosure

SPECIFICATIONS
Service: Oil free, clean dry air filtered to 40 microns.
Input Signal:
4-20 mA.
Air Supply: Minimum: 5 psig (0.3 bar) above maximum output; Maximum: 100 psig (6.9 bar).
Output: 3 to 15 psig (0.2 to 1.0 bar), 6 to 30 psig (0.4 to 2.1 bar).
Accuracy: ±0.1% of span.
Hysteresis: ±0.1% of span.
Repeatability: ±0.1% of span.
Deadband: 0.02% of span.
Power Requirement: Loop powered.
Temperature Limits: Operating: -40 to 160°F (-40 to 71°C); Storage: -40 to 200°F (-40 to 93°C).
Pressure Connections: 1/4" female NPT.
Electrical Connection: 1/2" female NPT.
Air Consumption:
0.025 scfm (0.01 l/s) at midrange typical.
Output Capacity: 4.5 scfm (2.1 l/s) at 25 psig (1.7 bar) supply; 12.0 scfm (5.7 l/s) at 100 psig (6.9 bar) supply.
Enclosure: Chromate-treated aluminum with epoxy paint.
Enclosure Rating: NEMA 4X (IP65) and intrinsically safe.
Weight: 0.8 lb (0.37 kg).
Agency Approvals: CE, CSA, FM.

FM Intrinsically Safe Ratings:
Class I, II, III, Division 1, Groups C, D, E, F and G; Class I, Zone 0, Group IIB; Class I, II and III, Division 2, Groups A, B, C, D, F and G.

CSA Intrinsically Safe Ratings:
Class I, Division 2, Groups A, B, C and D; Class II, Division 2, Groups F and G; Class III.