SPECIFICATIONS
Service: Compatible liquids and gases.
Wetted Materials: 17-4 PH Stainless Steel.
Accuracy: ±0.25% FS.
Stability: ±0.2 % of F.S. for 1-year (non-cumulative).
Temperature Limits: DIN Models: -22 to 260°F (-40 to 125°C); Cable Models: -5 to 180°F (-20 to 80°C).
Pressure Limits: 2 x FS.
Thermal Effect: 1.5% FS.
Power Requirements: 24 VAC.
Output: 4-20 mA DC or 0-5 VDC 2-wire.
Loop Resistance: 850 ohms @24 VDC.
Electrical Connection: DIN Connector or 3 ft cable.
Process Connection: 1/4" male NPT.
Enclosure: NEMA 4 (IP65).
Weight: 1 lb (100 g).
Agency Approvals: CE, UL.