Home Product Information Free Literature International Distribution What's New About Us Contact Us
Quick Search
Dwyer Series
616
&
616C

Differential Pressure Transmitter
Ranges from 0-1" w.c. to 0 to 100 psid, Accuracy ±0.25% or ±1% F.S.

SPECIFICATIONS
Service: Air and non-combustible, compatible gases.
Wetted Materials: Consult factory.
Accuracy: 616: ±0.25% F.S.; 616C: ±1.0% F.S.
Stability: ±1% F.S./yr.
Temperature Limits: 0 to 140°F (-17.8 to 60°C).
Compensated Temperature Limits: 20 to 120°F (-6.67 to 48.9°C).
Pressure Limits: See chart on "Ordering" page.
Thermal Effect: ±0.02% F.S./°F (±0.0012% F.S./°C).
Power Requirements: 10-35 VDC (2-wire).
Output Signal: 4 to 20 mA.
Zero Adjustments: Potentiometers for zero and span.
Loop Resistance: DC; 0-1250 ohms maximum.
Current Consumption: DC; 38 mA maximum.
Electrical Connections: Screw-type terminal block.
Process Connections: Barbed, dual size to fit 1/8" and 3/16" (3.12 mm and 4.76 mm) I.D. rubber or vinyl tubing.
Weight: 1.8 oz (51 g).
Agency Approvals: CE on 616 only.

Home
Product Information
Free Literature
International Distribution
About Us
Contact Us
Terms & Conditions of Sale
Terms of Access