SPECIFICATIONS
Service: Clean/dry air and compatible combustible gases (see
Agency Approvals for FM ratings).
Wetted Materials: Consult factory.
Accuracy: ±0.5% or ±0.25% full scale.
Stability: ±0.5% F.S./yr.
Pressure Limits: 100 psig (6.89 bar); 15 psid (1.03 bar).
Temperature Limits: -20 to 185°F (-28 to 85°C).
Compensated Temperature Range: 0 to 160°F (-18 to 71°C).
Thermal Effect: 0.5% Accuracy: ±0.02% F.S./°F; 0.25%
Accuracy: ±0.01% F.S./°F.
Power Requirements: 12 to 36 VDC (2-wire).
Output Signal: 4 to 20 mA DC.
Zero and Span Adjustments: Potentiometers for zero and span.
Response Time: 250 ms.
Loop Resistance: DC: 0-1045 ohms maximum.
Current Consumption: 4-20 mA.
Electrical Connections: Screw terminals: two 1/2" female NPT
conduit.
Process Connections: Two 1/4" female NPT.
Enclosure Rating: NEMA 4X (IP65).
Mounting Orientation: Not position sensitive.
Weight: 2 lb (0.9 kg).
Agency Approvals: FM approved intrinsically safe for use in
Class I, Div. 1, Groups A, B, C, D; Class II, Div. 1, Groups E, F,
G; Class III, Div. 1 when wire with approved intrinsically safe barrier.
Entity parameters: Vmax=36 VDC; Imax=250 mA;
C=12 nF; L=0 mH. |