Digital Manometer
Single Pressure Measurement, Electronic Zeroing, ±1.5% Accuracy

SPECIFICATIONS
Service: Air and compatible gases.
Wetted Materials: Consult factory.
Accuracy: ±1.5% F.S. @ 72°F (22.2°C). Includes linearity and repeatability.
Pressure Hysteresis: ±0.1% of F.S.
Pressure Limits:
5 psig (.34 bar).
Temperature Limits: 0 to 140°F (-17.8 to 60°C).
Compensated Temperature Limits: 32 to 104°F (0 to 40°C).
Thermal Effect: 0.05% F.S./°F.
Display:
4 digit LCD (.425"H x .234"W digits).
Power Requirements: 9V alkaline battery. Battery included but not connected.
Process Connections: Barbed connection for use with 3/16" or 1/4" I.D. tubing.
Weight:
10.8 oz (306 g).
Agency Approvals: CE.